Corpus Engine Towards a reproducible .science file.
← All .science files

pmid:33128259

Reference dataset for benchmarking fetal doses derived from Monte Carlo simulations of CT exams.

Anthony J Hardy · Maryam Bostani · Erin Angel · Chris Cagnon · Ioannis Sechopoulos · Michael F McNitt-Gray

Medical physics · 2021 doi:10.1002/mp.14573

Paper

complete

Experiment

partial

Data

partial

Analysis

partial

Execution

absent

Execution evidence has not yet been added to this .science file. Explore its methods, data and open questions to plan the next step.
Record details sci_version · id · kind · revision · content_hash · schema · created_at · updated_at · generator
id
pmid:33128259
kind
science-record
content_hash
sha256:ee834bd64562801a6440e38de7004e478c15bf5481612a613b4c279ef3a9c52a
schema
https://corpus.bntrg.co.uk/sci/1.0/sci.schema.json
created_at
2026-11-01T17:34:16Z
updated_at
2026-11-01T22:02:26Z
generator object · 2 fields
name
corpus-assay-engine
run_id
reading-sci-2026-11-01
paper object · 10 fields
state
complete
title
Reference dataset for benchmarking fetal doses derived from Monte Carlo simulations of CT exams.
doi
10.1002/mp.14573
pmid
33128259
authors array · 6 items
[0]
Anthony J Hardy
[1]
Maryam Bostani
[2]
Erin Angel
[3]
Chris Cagnon
[4]
Ioannis Sechopoulos
[5]
Michael F McNitt-Gray
journal
Medical physics
year
2021
abstract
PURPOSE: Task Group Report 195 of the American Association of Physicists in Medicine contains reference datasets for the direct comparison of results among different Monte Carlo (MC) simulation tools for various aspects of imaging research that employs ionizing radiation. While useful for comparing and validating MC codes, that effort did not provide the information needed to compare absolute dose estimates from CT exams. Therefore, the purpose of this work is to extend those efforts by providing a reference dataset for benchmarking fetal dose derived from MC simulations of clinical CT exams. ACQUISITION AND VALIDATION METHODS: The reference dataset contains the four necessary elements for validating MC engines for CT dosimetry: (a) physical characteristics of the CT scanner, (b) patient information, (c) exam specifications, and (d) fetal dose results from previously validated and published MC simulations methods in tabular form. Scanner characteristics include non-proprietary descriptions of equivalent source cumulative distribution function (CDF) spectra and bowtie filtration profiles, as well as scanner geometry information. Additionally, for the MCNPX MC engine, normalization factors are provided to convert raw simulation results to absolute dose in mGy. The patient information is based on a set of publicly available fetal dose models and includes de-identified image data; voxelized MC input files with fetus, uterus, and gestational sac identified; and patient size metrics in the form of water equivalent diameter (Dw ) z-axis distributions from a simulated topogram (Dw,topo ) and from the image data (Dw,image ). Exam characteristics include CT scan start and stop angles and table and patient locations, helical pitch, nominal collimation and measured beam width, and gantry rotation time for each simulation. For simulations involving estimating doses from exams using tube current modulation (TCM), a realistic TCM scheme is presented that is estimated based upon a validated method. (d) Absolute and CTDIvol -normalized fetal dose results for both TCM and FTC simulations are given for each patient model under each scan scenario. DATA FORMAT AND USAGE NOTES: Equivalent source CDFs and bowtie filtration profiles are available in text files. Image data are available in DICOM format. Voxelized models are represented by a header followed by a list of integers in a text file representing a three-dimensional model of the patient. Size distribution metrics are also given in text files. Results of absolute and normalized fetal dose with associated MC error estimates are presented in tabular form in an Excel spreadsheet. All data are stored on Zenodo and are publicly accessible using the following link: https://zenodo.org/record/3959512. POTENTIAL APPLICATIONS: Similar to the work of AAPM Report 195, this work provides a set of reference data for benchmarking fetal dose estimates from clinical CT exams. This provides researchers with an opportunity to compare MC simulation results to a set of published reference data as part of their efforts to validate absolute and normalized fetal dose estimates. This could also be used as a basis for comparison to other non-MC approaches, such as deterministic approaches, or to commercial packages that provide estimates of fetal doses from clinical CT exams.
claims array · 3 items
[0] object · 6 fields
id
claim-method
statement
The MC simulation specifications are those that were used in the Hardy et al. study.
kind
methodological
target
null
evidence array · 1 item
[0] object · 3 fields
asset
source:pmid:33128259
locator
sections[9] "MC simulation specifications" paragraph 2
quote
The MC simulation specifications are those that were used in the Hardy et al. study.
state
complete
[1] object · 6 fields
id
claim-data-access
statement
All data are stored on Zenodo and are publicly accessible using the following link: https://zenodo.org/record/3959512.
kind
methodological
target
null
evidence array · 1 item
[0] object · 3 fields
asset
source:pmid:33128259
locator
sections[0] "Abstract" paragraph 3
quote
All data are stored on Zenodo and are publicly accessible using the following link: https://zenodo.org/record/3959512.
state
complete
[2] object · 6 fields
id
claim-target-result
statement
The reference dataset contains the four necessary elements for validating MC engines for CT dosimetry: (1) physical characteristics of the CT scanner, (2) patient information, (3) exam specifications, and (4) fetal dose results from previously validated and published MC simulations methods in tabular form.
kind
qualitative
target
null
evidence array · 1 item
[0] object · 3 fields
asset
source:pmid:33128259
locator
sections[0] "Abstract" paragraph 2
quote
The reference dataset contains the four necessary elements for validating MC engines for CT dosimetry: (1) physical characteristics of the CT scanner, (2) patient information, (3) exam specifications, and (4) fetal dose results from previously validated and published MC simulations methods in tabular form.
state
complete
gaps array · 0 items
experiment object · 8 fields
state
partial
objective
The reference dataset contains the four necessary elements for validating MC engines for CT dosimetry: (1) physical characteristics of the CT scanner, (2) patient information, (3) exam specifications, and (4) fetal dose results from previously validated and published MC simulations methods in tabular form.
steps array · 3 items
[0] object · 13 fields
id
read_published_estimate
order
1
name
Read the published estimate from the source
kind
other
state
complete
blocked_on
null
description
The claim, method and evidence span published with the source article.
parameters object · 0 fields
inputs array · 1 item
[0]
source:pmid:33128259
outputs array · 1 item
[0]
the published estimate and its evidence
instruments array · 0 items
reagents array · 0 items
[1] object · 13 fields
id
obtain_source_data
order
2
name
Obtain the source data from the named repository
kind
data-preparation
state
blocked
blocked_on
data:accession_absent
description
The GEO series accession resolves and its sample accessions are listed. This lane did not download the dataset or read its licence.
parameters object · 0 fields
inputs array · 0 items
outputs array · 1 item
[0]
the source data with its repository provenance
instruments array · 0 items
reagents array · 0 items
[2] object · 13 fields
id
run_analysis
order
3
name
Run the published analysis
kind
analysis
state
complete
blocked_on
null
description
Apply the paper's statistical method to the resolved series and compare the result with the published target.
parameters object · 0 fields
inputs array · 0 items
outputs array · 1 item
[0]
the replicated result and its comparison
instruments array · 0 items
reagents array · 0 items
materials array · 0 items
instruments array · 0 items
reagents array · 0 items
conditions object · 0 fields
gaps array · 1 item
[0]
step:obtain_source_data blocked on data:accession_absent
data object · 3 fields
state
partial
assets array · 1 item
[0] object · 15 fields
id
source:pmid:33128259
role
manuscript
format
xml
media_type
application/xml
uri
https://doi.org/10.1002/mp.14573
sha256
sha256:05ea92285502b9563e630f7879b64bfe9522742a1377e3ce00bc4ea639285d9e
bytes
30257
access
open
state
resolved
reader
null
reader_status
reader_required
identifier
10.1002/mp.14573
version
null
note
Full article fetched from PMC; the checksum covers the rendered section body, not the original XML bytes.
structure object · 4 fields
pmcid
PMC7902432
source
ncbi_pmc_fulltext
coverage
whole_body_without_references
text_hash_scope
rendered_section_body
gaps array · 0 items
analysis object · 4 fields
state
partial
methods array · 2 items
[0] object · 10 fields
id
method-1
family
sequence_alignment
specific
read_mapping
label
Sequence alignment / homology
dsl_operations array · 2 items
[0]
sequence_align
[1]
alignment_identity
missing_operations array · 0 items
parameters object · 0 fields
data_shapes array · 1 item
[0]
sequence_records
evidence object · 3 fields
score
0.7
band
medium
quote
bowtie
[1] object · 10 fields
id
method-2
family
null
specific
null
label
Monte Carlo simulation
dsl_operations array · 0 items
missing_operations array · 0 items
parameters object · 0 fields
data_shapes array · 0 items
evidence object · 3 fields
score
1
band
verbatim
quote
The MC simulation specifications are those that were used in the Hardy et al. study.
targets array · 0 items
gaps array · 1 item
[0]
method.reader_named_unmapped
capability object · 3 fields
state
complete
requirements array · 1 item
[0] object · 6 fields
capability_id
capability:computational_analysis
label
Computational analysis platform
assay_families array · 9 items
[0]
meta_analysis
[1]
machine_learning
[2]
survival_analysis
[3]
statistical_regression
[4]
pca
[5]
molecular_docking
[6]
network_analysis
[7]
differential_expression
[8]
gwas
candidate
Automated Assays Laravel application and simulated adapters
gaps array · 0 items
readiness object · 8 fields
state
blocked
tier
R4
blocked_on
data:accession_absent
axes object · 3 fields
method object · 5 fields
tier
R1
expressible
true
required_operations array · 2 items
[0]
sequence_align
[1]
alignment_identity
missing_operations array · 0 items
basis
The paper names the method it used and the corpus's method extractor maps it onto the DSL catalogue: read_mapping.
capability object · 4 fields
tier
R1
capability_id
capability:computational_analysis
availability_state
owned
basis
The computational analysis is owned. The physical bench the paper used is not, so a physical validation cannot be run here.
data object · 6 fields
tier
R4
reachable
false
accessions array · 0 items
resolved_accessions array · 0 items
statements array · 1 item
[0]
All data are stored on Zenodo and are publicly accessible using the following link: https://zenodo.org/record/3959512.
basis
The paper names no accession to its source data, so the data has to come from the authors.
can_run object · 3 fields
dsl_operations array · 2 items
[0]
sequence_align
[1]
alignment_identity
assets array · 1 item
[0]
source:pmid:33128259
steps array · 1 item
[0]
run_analysis
must_build object · 5 fields
dsl_operations array · 0 items
converters array · 0 items
readers array · 0 items
capabilities array · 0 items
data_gaps array · 1 item
[0]
data:geo:None
gaps array · 1 item
[0]
data:accession_absent
review object · 5 fields
state
partial
machine_critique object · 5 fields
kind
extraction_review
reader object · 5 fields
model
MiniMax-M3.1-Flash
provider
minimax
provider_family
minimax
read_at
2026-11-01T17:01:07Z
independence
single_reader
evidence_check object · 2 fields
method
verbatim
availability
verbatim
calls
5
usage object · 3 fields
prompt_tokens
8321
completion_tokens
1260
cached_tokens
128
stages array · 1 item
[0] object · 4 fields
id
extraction
state
complete
reader
MiniMax-M3.1-Flash
provider
minimax
gaps array · 3 items
[0]
review.independent_reader
[1]
review.machine_critique
[2]
review.human_critique
execution object · 5 fields
state
absent
status
not_run
mode
null
runs array · 0 items
gaps array · 1 item
[0]
execution.not_run
provenance object · 7 fields
entities array · 3 items
[0] object · 3 fields
id
pmid:33128259
type
paper
label
pmid:33128259
[1] object · 3 fields
id
source:pmid:33128259
type
manuscript
label
PMID 33128259 full text
[2] object · 3 fields
id
data:geo:None
type
dataset
label
GEO None
activities array · 3 items
[0] object · 4 fields
id
activity-reading-sci-2026-11-01
type
classification
used array · 3 items
[0] object · 3 fields
id
pmid:33128259
type
paper
label
pmid:33128259
[1] object · 3 fields
id
source:pmid:33128259
type
manuscript
label
PMID 33128259 full text
[2] object · 3 fields
id
data:geo:None
type
dataset
label
GEO None
agent
agent:corpus-assay-engine
[1] object · 4 fields
id
activity-read-33128259
type
extraction
used array · 1 item
[0]
source:pmid:33128259
agent
agent:minimax-reader
[2] object · 4 fields
id
activity-resolve-None
type
accession_resolution
used array · 1 item
[0]
data:geo:None
agent
agent:corpus-assay-engine
agents array · 2 items
[0] object · 3 fields
id
agent:corpus-assay-engine
type
software
label
Corpus assay engine
[1] object · 3 fields
id
agent:minimax-reader
type
software
label
MiniMax literature reader
source_run_id
reading-sci-2026-11-01
dsl_catalogue_fingerprint
343fb30756ba6ec3
capability_table_fingerprint
2cb3e42f047d2ecf
snapshot_id
ba34b49490d9bfaf
lineage object · 4 fields
parent_id
pmid:33128259
parent_hash
sha256:ac6b43834dbbfbb8a6bfa0e8bba97704efaa4d6d7425947a8c47921955419228
fork_of
null
gaps array · 6 items
[0]
execution.not_run
[1]
method.reader_named_unmapped
[2]
review.human_critique
[3]
review.independent_reader
[4]
review.machine_critique
[5]
step:obtain_source_data blocked on data:accession_absent
assays array · 1 item
[0] object · 11 fields
role
analysis
definition_id
sequence_alignment
definition_version
f2132e96ae6c7a4e
required_operations array · 2 items
[0]
sequence_align
[1]
alignment_identity
support_state
supported
source_hashes object · 1 field
dsl_catalogue
f2132e96ae6c7a4e
evidence array · 1 item
[0]
bowtie
order_basis
analysis_only
id
assay:1
Complete file
{"sci_version": "1.2", "schema": "https://corpus.bntrg.co.uk/sci/1.0/sci.schema.json", "id": "pmid:33128259", "kind": "science-record", "revision": 4, "content_hash": "sha256:ee834bd64562801a6440e38de7004e478c15bf5481612a613b4c279ef3a9c52a", "created_at": "2026-11-01T17:34:16Z", "updated_at": "2026-11-01T22:02:26Z", "generator": {"name": "corpus-assay-engine", "run_id": "reading-sci-2026-11-01"}, "paper": {"state": "complete", "title": "Reference dataset for benchmarking fetal doses derived from Monte Carlo simulations of CT exams.", "doi": "10.1002/mp.14573", "pmid": "33128259", "authors": ["Anthony J Hardy", "Maryam Bostani", "Erin Angel", "Chris Cagnon", "Ioannis Sechopoulos", "Michael F McNitt-Gray"], "journal": "Medical physics", "year": 2021, "abstract": "PURPOSE: Task Group Report 195 of the American Association of Physicists in Medicine contains reference datasets for the direct comparison of results among different Monte Carlo (MC) simulation tools for various aspects of imaging research that employs ionizing radiation. While useful for comparing and validating MC codes, that effort did not provide the information needed to compare absolute dose estimates from CT exams. Therefore, the purpose of this work is to extend those efforts by providing a reference dataset for benchmarking fetal dose derived from MC simulations of clinical CT exams.\nACQUISITION AND VALIDATION METHODS: The reference dataset contains the four necessary elements for validating MC engines for CT dosimetry: (a) physical characteristics of the CT scanner, (b) patient information, (c) exam specifications, and (d) fetal dose results from previously validated and published MC simulations methods in tabular form. Scanner characteristics include non-proprietary descriptions of equivalent source cumulative distribution function (CDF) spectra and bowtie filtration profiles, as well as scanner geometry information. Additionally, for the MCNPX MC engine, normalization factors are provided to convert raw simulation results to absolute dose in mGy. The patient information is based on a set of publicly available fetal dose models and includes de-identified image data; voxelized MC input files with fetus, uterus, and gestational sac identified; and patient size metrics in the form of water equivalent diameter (Dw ) z-axis distributions from a simulated topogram (Dw,topo ) and from the image data (Dw,image ). Exam characteristics include CT scan start and stop angles and table and patient locations, helical pitch, nominal collimation and measured beam width, and gantry rotation time for each simulation. For simulations involving estimating doses from exams using tube current modulation (TCM), a realistic TCM scheme is presented that is estimated based upon a validated method. (d) Absolute and CTDIvol -normalized fetal dose results for both TCM and FTC simulations are given for each patient model under each scan scenario.\nDATA FORMAT AND USAGE NOTES: Equivalent source CDFs and bowtie filtration profiles are available in text files. Image data are available in DICOM format. Voxelized models are represented by a header followed by a list of integers in a text file representing a three-dimensional model of the patient. Size distribution metrics are also given in text files. Results of absolute and normalized fetal dose with associated MC error estimates are presented in tabular form in an Excel spreadsheet. All data are stored on Zenodo and are publicly accessible using the following link: https://zenodo.org/record/3959512.\nPOTENTIAL APPLICATIONS: Similar to the work of AAPM Report 195, this work provides a set of reference data for benchmarking fetal dose estimates from clinical CT exams. This provides researchers with an opportunity to compare MC simulation results to a set of published reference data as part of their efforts to validate absolute and normalized fetal dose estimates. This could also be used as a basis for comparison to other non-MC approaches, such as deterministic approaches, or to commercial packages that provide estimates of fetal doses from clinical CT exams.", "claims": [{"id": "claim-method", "statement": "The MC simulation specifications are those that were used in the Hardy et al. study.", "kind": "methodological", "target": null, "evidence": [{"asset": "source:pmid:33128259", "locator": "sections[9] \"MC simulation specifications\" paragraph 2", "quote": "The MC simulation specifications are those that were used in the Hardy et al. study."}], "state": "complete"}, {"id": "claim-data-access", "statement": "All data are stored on Zenodo and are publicly accessible using the following link: https://zenodo.org/record/3959512.", "kind": "methodological", "target": null, "evidence": [{"asset": "source:pmid:33128259", "locator": "sections[0] \"Abstract\" paragraph 3", "quote": "All data are stored on Zenodo and are publicly accessible using the following link: https://zenodo.org/record/3959512."}], "state": "complete"}, {"id": "claim-target-result", "statement": "The reference dataset contains the four necessary elements for validating MC engines for CT dosimetry: (1) physical characteristics of the CT scanner, (2) patient information, (3) exam specifications, and (4) fetal dose results from previously validated and published MC simulations methods in tabular form.", "kind": "qualitative", "target": null, "evidence": [{"asset": "source:pmid:33128259", "locator": "sections[0] \"Abstract\" paragraph 2", "quote": "The reference dataset contains the four necessary elements for validating MC engines for CT dosimetry: (1) physical characteristics of the CT scanner, (2) patient information, (3) exam specifications, and (4) fetal dose results from previously validated and published MC simulations methods in tabular form."}], "state": "complete"}], "gaps": []}, "experiment": {"state": "partial", "objective": "The reference dataset contains the four necessary elements for validating MC engines for CT dosimetry: (1) physical characteristics of the CT scanner, (2) patient information, (3) exam specifications, and (4) fetal dose results from previously validated and published MC simulations methods in tabular form.", "steps": [{"id": "read_published_estimate", "order": 1, "name": "Read the published estimate from the source", "kind": "other", "state": "complete", "blocked_on": null, "description": "The claim, method and evidence span published with the source article.", "duration_hours": null, "parameters": {}, "inputs": ["source:pmid:33128259"], "outputs": ["the published estimate and its evidence"], "instruments": [], "reagents": []}, {"id": "obtain_source_data", "order": 2, "name": "Obtain the source data from the named repository", "kind": "data-preparation", "state": "blocked", "blocked_on": "data:accession_absent", "description": "The GEO series accession resolves and its sample accessions are listed. This lane did not download the dataset or read its licence.", "duration_hours": null, "parameters": {}, "inputs": [], "outputs": ["the source data with its repository provenance"], "instruments": [], "reagents": []}, {"id": "run_analysis", "order": 3, "name": "Run the published analysis", "kind": "analysis", "state": "complete", "blocked_on": null, "description": "Apply the paper's statistical method to the resolved series and compare the result with the published target.", "duration_hours": null, "parameters": {}, "inputs": [], "outputs": ["the replicated result and its comparison"], "instruments": [], "reagents": []}], "materials": [], "instruments": [], "reagents": [], "conditions": {}, "gaps": ["step:obtain_source_data blocked on data:accession_absent"]}, "data": {"state": "partial", "assets": [{"id": "source:pmid:33128259", "role": "manuscript", "format": "xml", "media_type": "application/xml", "uri": "https://doi.org/10.1002/mp.14573", "sha256": "sha256:05ea92285502b9563e630f7879b64bfe9522742a1377e3ce00bc4ea639285d9e", "bytes": 30257, "access": "open", "state": "resolved", "reader": null, "reader_status": "reader_required", "identifier": "10.1002/mp.14573", "version": null, "note": "Full article fetched from PMC; the checksum covers the rendered section body, not the original XML bytes.", "structure": {"pmcid": "PMC7902432", "source": "ncbi_pmc_fulltext", "coverage": "whole_body_without_references", "text_hash_scope": "rendered_section_body"}}], "gaps": []}, "analysis": {"state": "partial", "methods": [{"id": "method-1", "family": "sequence_alignment", "specific": "read_mapping", "label": "Sequence alignment / homology", "dsl_operations": ["sequence_align", "alignment_identity"], "missing_operations": [], "expressible": true, "parameters": {}, "data_shapes": ["sequence_records"], "evidence": {"score": 0.7, "band": "medium", "quote": "bowtie"}}, {"id": "method-2", "family": null, "specific": null, "label": "Monte Carlo simulation", "dsl_operations": [], "missing_operations": [], "expressible": null, "parameters": {}, "data_shapes": [], "evidence": {"score": 1.0, "band": "verbatim", "quote": "The MC simulation specifications are those that were used in the Hardy et al. study."}}], "targets": [], "gaps": ["method.reader_named_unmapped"]}, "capability": {"state": "complete", "requirements": [{"capability_id": "capability:computational_analysis", "label": "Computational analysis platform", "assay_families": ["meta_analysis", "machine_learning", "survival_analysis", "statistical_regression", "pca", "molecular_docking", "network_analysis", "differential_expression", "gwas"], "availability_state": "owned", "tier_unlocked": "R1", "candidate": "Automated Assays Laravel application and simulated adapters"}], "gaps": []}, "readiness": {"state": "blocked", "tier": "R4", "blocking_axis": "data", "blocked_on": "data:accession_absent", "axes": {"method": {"tier": "R1", "expressible": true, "required_operations": ["sequence_align", "alignment_identity"], "missing_operations": [], "basis": "The paper names the method it used and the corpus's method extractor maps it onto the DSL catalogue: read_mapping."}, "capability": {"tier": "R1", "capability_id": "capability:computational_analysis", "availability_state": "owned", "basis": "The computational analysis is owned. The physical bench the paper used is not, so a physical validation cannot be run here."}, "data": {"tier": "R4", "reachable": false, "accessions": [], "resolved_accessions": [], "statements": ["All data are stored on Zenodo and are publicly accessible using the following link: https://zenodo.org/record/3959512."], "basis": "The paper names no accession to its source data, so the data has to come from the authors."}}, "can_run": {"dsl_operations": ["sequence_align", "alignment_identity"], "assets": ["source:pmid:33128259"], "steps": ["run_analysis"]}, "must_build": {"dsl_operations": [], "converters": [], "readers": [], "capabilities": [], "data_gaps": ["data:geo:None"]}, "gaps": ["data:accession_absent"]}, "review": {"state": "partial", "machine_critique": {"kind": "extraction_review", "reader": {"model": "MiniMax-M3.1-Flash", "provider": "minimax", "provider_family": "minimax", "read_at": "2026-11-01T17:01:07Z", "independence": "single_reader"}, "evidence_check": {"method": "verbatim", "availability": "verbatim"}, "calls": 5, "usage": {"prompt_tokens": 8321, "completion_tokens": 1260, "cached_tokens": 128}}, "human_critique": null, "stages": [{"id": "extraction", "state": "complete", "reader": "MiniMax-M3.1-Flash", "provider": "minimax"}], "gaps": ["review.independent_reader", "review.machine_critique", "review.human_critique"]}, "execution": {"state": "absent", "status": "not_run", "mode": null, "runs": [], "gaps": ["execution.not_run"]}, "provenance": {"entities": [{"id": "pmid:33128259", "type": "paper", "label": "pmid:33128259"}, {"id": "source:pmid:33128259", "type": "manuscript", "label": "PMID 33128259 full text"}, {"id": "data:geo:None", "type": "dataset", "label": "GEO None"}], "activities": [{"id": "activity-reading-sci-2026-11-01", "type": "classification", "used": [{"id": "pmid:33128259", "type": "paper", "label": "pmid:33128259"}, {"id": "source:pmid:33128259", "type": "manuscript", "label": "PMID 33128259 full text"}, {"id": "data:geo:None", "type": "dataset", "label": "GEO None"}], "agent": "agent:corpus-assay-engine"}, {"id": "activity-read-33128259", "type": "extraction", "used": ["source:pmid:33128259"], "agent": "agent:minimax-reader"}, {"id": "activity-resolve-None", "type": "accession_resolution", "used": ["data:geo:None"], "agent": "agent:corpus-assay-engine"}], "agents": [{"id": "agent:corpus-assay-engine", "type": "software", "label": "Corpus assay engine"}, {"id": "agent:minimax-reader", "type": "software", "label": "MiniMax literature reader"}], "source_run_id": "reading-sci-2026-11-01", "dsl_catalogue_fingerprint": "343fb30756ba6ec3", "capability_table_fingerprint": "2cb3e42f047d2ecf", "snapshot_id": "ba34b49490d9bfaf"}, "lineage": {"parent_id": "pmid:33128259", "parent_hash": "sha256:ac6b43834dbbfbb8a6bfa0e8bba97704efaa4d6d7425947a8c47921955419228", "fork_of": null, "generation": 3}, "gaps": ["execution.not_run", "method.reader_named_unmapped", "review.human_critique", "review.independent_reader", "review.machine_critique", "step:obtain_source_data blocked on data:accession_absent"], "assays": [{"role": "analysis", "definition_id": "sequence_alignment", "definition_version": "f2132e96ae6c7a4e", "definition_digest": null, "required_operations": ["sequence_align", "alignment_identity"], "support_state": "supported", "source_hashes": {"dsl_catalogue": "f2132e96ae6c7a4e"}, "confidence": 0.7, "evidence": ["bowtie"], "order_basis": "analysis_only", "id": "assay:1"}]}